Pengaruh Variasi Waktu Inkubasi terhadap Kadar Hemoglobin Menggunakan Metode Sahli

The Effect of Incubation Time on Hemoglobin Levels using Sahli Method

Authors

  • Rinny Ardina Universitas Muhammadiyah Palangkaraya
  • Yemimasike Putri Universitas Muhammadiyah Palangkaraya

DOI:

https://doi.org/10.33084/bjmlt.v2i1.1084

Keywords:

hemoglobin, incubation time, Sahli method

Abstract

Several clinical laboratory and community health centers in Palangka Raya still use a simple method to determine hemoglobin levels with Sahli method. There are mamy differences in procedures related to incubation time in Sahli method of hemoglobin examination. There are those who don’t use incubation, incubation for 3 minutes or incubation for 5 minutes. This study aimed to determine the effect of icubation time on hemoglobin levels using the Sahli method. This study was experimental study, where hemoglobin levels are measured by Sahli method with incubation time variations of 0 minutes, 3 minutes, 5 minutes, 8 minutes, and 10 minutes. A total of 21 blood samples were obtained by purposive sampling technique. The data obtained were statistically analyzed using the One Way ANNOVA test. The results showed there are significant effect of incubation time (0 minutes, 3 minutes, 5 minutes, 8 minutes and 10 minutes) on hemoglobin levels using Sahli method (p = 0.00). Increased hemoglobin levels occur with increasing incubation time. Where the lowest value of the average hemoglobin level at the measurement of 0 minutes was 10.9 g / dl and the highest value on the measurement of 10 minutes was 14.2 g / dl. It is important to laboratory personnel to incubate blood according to the procedures established by the Sahli method, because errors in the analytical stage contribute 25% to the causes of errors in laboratory result.

Downloads

Download data is not yet available.

References

Bain, B. J., Bates, I., & Laffan, M. A. (2017). Dacie and Lewis Practical Haematology (Twelfth Edition) (Twelfth Ed; M. Emeritus S. MITCHELL LEWIS, BSc & F. FRCPath, DCP, eds.). Elsevier B.V.
Barduagni, P., Ahmed, A. S., Curtale, F., Raafat, M., & Soliman, L. (2003). Performance of Sahli and colour scale methods in diagnosing anaemia among school children in low prevalence areas. Tropical Medicine and International Health, 8(7), 615–618. https://doi.org/10.1046/j.1365-3156.2003.01062.x.
Departemen Kesehatan Republik Indonesia. 2008. Pedoman Praktik Laboratorium yang Benar. Jakarta : Depkes RI.
Fitri, A. 2012 . Pengaruh Warna Standar Terhadap Hasil Pemeriksaan Hemoglobin Metode Sahli. Karya Tulis Ilmiah. Program Studi Analis Kesehatan. Fakultas Ilmu Kesehatan. Universitas Muhammadiyah Palangkaraya: Palangka Raya.
Gandasoebrata R. 2016. Penuntun Pemeriksaan Klinik. PT. Dian Rakyat: Jakarta.
Higgins, C. (2005). Hemoglobin and its measurement. Acutecaretesting.Org, (July), 1–10. Retrieved from https://acutecaretesting.org/~/media/acutecaretesting/files/pdf/hemoglobin-and-its-measurement.pdf.
Husin, H.Y. 2013. Pengaruh Waktu Inkubasi Pemeriksaan Hemoglobin Metode Sahli. Karya Tulis Ilmiah. Program Studi Analis Kesehatan. Fakultas Ilmu Kesehatan. Universitas Muhammadiyah Palangkaraya: Palangka Raya.
Mengko, R. 2013. Instrumentasi Laboratorium Klinik. Penerbit ITB: Bandung.
Srivastava, T., Negandhi, H., Neogi, S. B., Sharma, J., & Saxena, R. (2014). Methods for Hemoglobin Estimation: A Review of “ What Works .” Journal of Hematology and Transfusion, 2(3), 2005–2006.

Downloads

Published

2019-10-31

How to Cite

Ardina, R., & Putri, Y. (2019). Pengaruh Variasi Waktu Inkubasi terhadap Kadar Hemoglobin Menggunakan Metode Sahli: The Effect of Incubation Time on Hemoglobin Levels using Sahli Method. Borneo Journal of Medical Laboratory Technology, 2(1), 87–91. https://doi.org/10.33084/bjmlt.v2i1.1084